Submitted by Kim Egekjaer on Wed, 10/31/2012 - 00:00
Forums

We have seen some problems on newer InterForm400 versions when it comes to printing on Printronix printers. The reason is, that the ZPL language (or rather how Zebra printers works) has changed a bit over the years so the output from InterForm400 has also changed a little bit. This has caused a printing problem on some Printronix printers when upgrading to a 2011 or 2012 Version of InterForm400.

There are two solutions to this problem:

  1. Doing a firmware upgrade of the Printronix printers. I have a special firmware that you can get if interested.
  2. If you are ONLY printing to your ZPL printers from InterForm400 and no other applications, then you can consider a change in the InterForm400 configuration as alternative. This will change the ZPL printers configuration and likely making it impossible to print from other applications until you change the configuration back. This is a global change (for all ZPL printouts from InterForm400). You can change it by selecting this in InterForm400:

70. Configuration and licenses
2. Configure InterForm 400
Then press Enter multiple times until you get to this screen:

        Configure InterForm 400                                      APF101D

                                                                           14/15

 How to manage command prefixes and delimiter on Zebra printers.                     



 Zebra principle . .  2   1=Use save and restore printer configuration.       

                            (will not work correct on all printer models)     

                          2=Set values at the end of every printout.                                                                                         



         - Control commands prefix           Hex  10   Default = X'7E' (tilde)                                                                                

         - Format commands prefix            Hex  1E   Default = X'5E' (caret)                                                                                

         - Delimiter                         Hex  2C   Default = X'2C' (comma)                                                                               



 F3=Exit                                                     F12=Cancel       

                                                                                

If you set the control command prefix to hex 10 and the format command prefix to hex 1E like above, then the ZPL output will print both Zebra and Printronix printers, that are ZPLII compatible.