Submitted by Anonymous (not verified) on Sat, 01/01/2005 - 00:00 Forums BlueSeries I am using the IBM 7852 Option modem as recommended but get the error message: CMN1054 - No response to EOP repeated 3 times. Re: Error message: CMN1054 - No response to EOP repeated.. Check the "Modem Product Revision" in the fax line description using option 12 on the main menu. Modem Product Revision" MUST read " +FREV=0416D ". All other versions e.g. "+FREV=0313D " is obsolete ! You can upgrade your modem using the firmware available on your BlueSeries eXpress'it CD on :\IBM Firmware Log in or register to post comments Log in or register to post comments
Re: Error message: CMN1054 - No response to EOP repeated.. Check the "Modem Product Revision" in the fax line description using option 12 on the main menu. Modem Product Revision" MUST read " +FREV=0416D ". All other versions e.g. "+FREV=0313D " is obsolete ! You can upgrade your modem using the firmware available on your BlueSeries eXpress'it CD on :\IBM Firmware Log in or register to post comments
Re: Error message: CMN1054 - No response to EOP repeated..
Check the "Modem Product Revision" in the fax line description using
option 12 on the main menu.
Modem Product Revision" MUST read " +FREV=0416D ".
All other versions e.g. "+FREV=0313D " is obsolete !
You can upgrade your modem using the firmware available on your
BlueSeries eXpress'it CD on :\IBM Firmware